| Main | |
| Range | Go Series |
| Product name | GoLogic EM3000 |
| Device short name | GLEM3200 LCD |
| Product or component type | Energy meter |
| Complementary | |
| Power quality analysis | total harmonic distortion individual harmonics |
| Device application | Energy monitoring |
| Type of measurement | Current Voltage Frequency Power factor average Power factor per phase RPM Harmonic distortion (I THD & U THD) Power total Power per phase Active energy |
| Metering type | Average current Iavg Phase currents Active, reactive, apparent power (signed, four quadrant) Active, reactive, apparent energy (signed, two quadrant) Average voltage Vavg Calculated neutral current Voltage U21, U32, U13, V1, V2, V3 |
| Counter functions | ON hour counting ON-load hour counting Power interruption |
| [Us] rated supply voltage | 48…277 V AC/DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 1 A 5 A |
| type of network | 3P 2P + N 1P + N 3P + N 2P |
| Maximum power consumption in W | 2 W at 24 V |
| Display type | LCD display |
| Display colour | Monochrome |
| Display digits | 12 digit(s) |
| Communication of data | Reading of measurements All counters Revolution speed Last cleared log Instantaneous and demand values |
| Tamperproof of settings | Protected by access code |
| Sampling rate | 32 samples/cycle |
| Measurement current | 10…6000 mA |
| Signal | Voltage (impedance 5 MOhm)4 x Current 0.005…10 A (impedance 0.3 MOhm)6 x |
| Measurement voltage | 46…277 V AC 50…60 Hz between phase and neutral 80…480 V AC 50…60 Hz between phases 100…999000 V AC 50…60 Hz with external VT |
| Frequency measurement range | 45…65 Hz |
| Measurement accuracy | Current +/- 0.5 % Voltage +/- 0.5 % Frequency +/- 0.05 % 48…52 Hz / 58…62 Hz Frequency +/- 0.2 % 30…70 Hz Power factor +/- 0.01 Reactive power +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Active energy +/- 0.5 % Reactive energy +/- 2 % Apparent energy +/- 0.5 % Harmonic distortion (I THD & U THD) +/- 5 % |
| Accuracy class | Class 0.5 active energy conforming to IEC 62053-22 Class 2 reactive energy conforming to IEC 62053-24 |
| Demand intervals | 1 s |
| Local signalling | Green LED: activity Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) LED: voltage indication |
| Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
| Communication port support | Screw terminal: RS485 |
| Data recording | Energy consumption logs |
| Material | Polycarbonate |
| Flame retardance | V-0 conforming to UL 94 |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Provided equipment | Installation guide User manual |
| Installation category | III |
| Type of installation | Indoor installation |
| Measurement category | Category III 0…480 V |
| Electrical insulation class | Class II |
| Connections – terminals | Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s) |
| Tightening torque | Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver Communication: 0.5…0.6 N.m Philips no 1 screwdriver |
| Wire stripping length | Current circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm Communication: 7 mm |
| Standards | IEC 61010-1:ed. 3 UL 61010-1:ed. 3 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1-12 C-Tick |
| Width | 96 mm |
| Depth | Outside : 13.9 mm Panel : 50.4 mm |
| Height | 96 mm |
| Net weight | 300 g |
| Environment | |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 Emission tests conforming to CISPR 11 Emission tests conforming to IEC 61326-1 |
| Overvoltage category | III |
| IP degree of protection | IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C |
| Pollution degree | 2 |
| Ambient air temperature for operation | -10…60 °C |
| Ambient air temperature for storage | -25…70 °C |
| Operating altitude | <= 2000 m |
| service life | 7 year(s) |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.65 cm |
| Package 1 Width | 21.08 cm |
| Package 1 Length | 24.13 cm |
| Package 1 Weight | 544.311 g |